EMERSON ? ASCO Solenoid Valve E314K035S1N01-24V 50HZ, 3 port(s) , NC, 24 V ac, 1/4in
Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
EMERSON – ASCOSupply Voltage
24 V ac
Number of Ports
3
Connection Size
1/4in
Connection
1/4 in G Female
Operation
Direct
Default Valve Position
NC
Suitable Applications
Air, Oil, Water
Type
3/2
Orifice Diameter
2.4mm
Series
E314K
Body Material
Brass
Maximum Working Pressure
10 (Air) bar, 6 (Oil) bar, 8 (Water) bar
Operating Temperature Range
-25 → +90 °C
Minimum Operating Temperature
-25°C
Thread Standard or Connection Type
G
Maximum Operating Temperature
+90°C
Connection Gender
Female
Flow Factor Kv
0.17m³/h
Maximum Opening Time
25ms
Χώρα Προέλευσης
Poland
Λεπτομέρειες Προϊόντος
Three-way, Direct Operated Valves, N/C
Direct operated solenoid valves with a stainless steel or brass body and NBR rubber seals. Fitted with a manual override and suitable for use with air, inert gases oil and water. ASCOs 314 series solenoid valves provide a compact solution for controlling single-acting actuators or filling and draining systems.
3 Way Inert Gases and Fluid Valves
Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left hand side of the diagram describes the valves operation when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and this is described on the right hand side of the diagram, see the typical schematic diagram below.,The 3//2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2//2-way valves as two-way.,The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications will indicate the appropriate connections and pressure capabilities should an alternative circuit function be required.
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη
Παρακαλούμε ελέγξτε ξανά αργότερα.
€ 176,47
Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
€ 218,82
Μονάδας Με Φ.Π.Α
1
€ 176,47
Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
€ 218,82
Μονάδας Με Φ.Π.Α
1
Αγοράστε μαζικά
Quantity Ποσότητα | Τιμή μονάδας |
---|---|
1 - 4 | € 176,47 |
5+ | € 173,62 |
Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
EMERSON – ASCOSupply Voltage
24 V ac
Number of Ports
3
Connection Size
1/4in
Connection
1/4 in G Female
Operation
Direct
Default Valve Position
NC
Suitable Applications
Air, Oil, Water
Type
3/2
Orifice Diameter
2.4mm
Series
E314K
Body Material
Brass
Maximum Working Pressure
10 (Air) bar, 6 (Oil) bar, 8 (Water) bar
Operating Temperature Range
-25 → +90 °C
Minimum Operating Temperature
-25°C
Thread Standard or Connection Type
G
Maximum Operating Temperature
+90°C
Connection Gender
Female
Flow Factor Kv
0.17m³/h
Maximum Opening Time
25ms
Χώρα Προέλευσης
Poland
Λεπτομέρειες Προϊόντος
Three-way, Direct Operated Valves, N/C
Direct operated solenoid valves with a stainless steel or brass body and NBR rubber seals. Fitted with a manual override and suitable for use with air, inert gases oil and water. ASCOs 314 series solenoid valves provide a compact solution for controlling single-acting actuators or filling and draining systems.
3 Way Inert Gases and Fluid Valves
Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left hand side of the diagram describes the valves operation when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and this is described on the right hand side of the diagram, see the typical schematic diagram below.,The 3//2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2//2-way valves as two-way.,The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications will indicate the appropriate connections and pressure capabilities should an alternative circuit function be required.