Technical Document
Specifications
Brand
SchurterFuse Size
5 x 20 mm, 6.3 x 32 mm
Mounting Style
PCB Mount
Clip Material
Brass
Width
5.8mm
Length
12mm
Height
11.5mm
Current Rating
16A
Contact Plating
Tin
Series
751
Voltage Rating
600V ac/dc
For Use With
5 x 20 mm Fuse, 6.3 x 32 mm Fuse
Country of Origin
Switzerland
Product details
Schurter Fuseholder Mounting Accessories
Schurter Fuse Clips can be used in conjunction with schurter fuses to provide primary protection for electronic circuits. Fuse clips are available in a different mounting styles including solder and screw.
Panel Mounting
CATEGORIES OF PROTECTION AGAINST ELECTRIC SHOCK,PC1: No integral protection against electric shock. If required, designers must provide additional protection against electric shock on equipment.,PC2: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 standard test finger, when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.,PC3: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 1mm diameter rigid test wire when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.
P.O.A.
Each (In a Pack of 50) (Exc. Vat)
50
P.O.A.
Each (In a Pack of 50) (Exc. Vat)
50
Stock information temporarily unavailable.
Please check again later.
Technical Document
Specifications
Brand
SchurterFuse Size
5 x 20 mm, 6.3 x 32 mm
Mounting Style
PCB Mount
Clip Material
Brass
Width
5.8mm
Length
12mm
Height
11.5mm
Current Rating
16A
Contact Plating
Tin
Series
751
Voltage Rating
600V ac/dc
For Use With
5 x 20 mm Fuse, 6.3 x 32 mm Fuse
Country of Origin
Switzerland
Product details
Schurter Fuseholder Mounting Accessories
Schurter Fuse Clips can be used in conjunction with schurter fuses to provide primary protection for electronic circuits. Fuse clips are available in a different mounting styles including solder and screw.
Panel Mounting
CATEGORIES OF PROTECTION AGAINST ELECTRIC SHOCK,PC1: No integral protection against electric shock. If required, designers must provide additional protection against electric shock on equipment.,PC2: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 standard test finger, when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.,PC3: With integral protection against electric shock. Fuse-holders shall have live parts inaccessible to IEC529 1mm diameter rigid test wire when fully assembled, without fuse carrier or fuse in place and when fuse carrier, with fuse is being inserted or withdrawn.