Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max

Κωδικός Προϊόντος της RS: 410-488Κατασκευαστής: ParkerΚωδικός Κατασκευαστή: PRT-C10
brand-logo

Τεχνικό φυλλάδιο

Προδιαγραφές

Brand

Parker

Maximum Time

30s

Minimum Time

0.1s

Maximum Operating Temperature

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-15°C

Χώρα Προέλευσης

France

Λεπτομέρειες Προϊόντος

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

Μπορεί να σας ενδιαφέρει
Parker T3P10 series 0.5s to 6s Pneumatic Timer, 7 bar max
P.O.A.Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
Parker T3P10 series 2.5s to 25s Pneumatic Timer, 7 bar max
P.O.A.Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α

Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη

Παρακαλούμε ελέγξτε ξανά αργότερα.

Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη

€ 312,81

Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α

€ 387,88

Μονάδας Με Φ.Π.Α

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max

€ 312,81

Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α

€ 387,88

Μονάδας Με Φ.Π.Α

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη

Αγοράστε μαζικά

Quantity ΠοσότηταΤιμή μονάδας
1 - 4€ 312,81
5+€ 304,89
Μπορεί να σας ενδιαφέρει
Parker T3P10 series 0.5s to 6s Pneumatic Timer, 7 bar max
P.O.A.Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
Parker T3P10 series 2.5s to 25s Pneumatic Timer, 7 bar max
P.O.A.Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α

Τεχνικό φυλλάδιο

Προδιαγραφές

Brand

Parker

Maximum Time

30s

Minimum Time

0.1s

Maximum Operating Temperature

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-15°C

Χώρα Προέλευσης

France

Λεπτομέρειες Προϊόντος

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

Μπορεί να σας ενδιαφέρει
Parker T3P10 series 0.5s to 6s Pneumatic Timer, 7 bar max
P.O.A.Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
Parker T3P10 series 2.5s to 25s Pneumatic Timer, 7 bar max
P.O.A.Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α