Allen Bradley Guardmaster micro 400 Series GuardShield Light Curtain, Sender & Receiver, 32 Beam(s), 30mm Resolution

Τεχνικό φυλλάδιο
Προδιαγραφές
Range
GuardShield
Series
micro 400
Beam Resolution
30mm
Component Type
Receiver, Sender
Safety Type
2
SIL IEC 61508
2
PL EN ISO 13849-1
d
Number Of Beams
32
Protective Height
480mm
Minimum Scanning Distance
0m
Maximum Scanning Distance
18m
Maximum Response Time
15.8 ms
Length
40mm
Supply Voltage
24 V dc
Height
650mm
Dimensions
30 x 40 x 650 mm
Application
Hand
Width
30mm
Terminal Type
5-Pin M12 Connector
Χώρα Προέλευσης
Switzerland
Λεπτομέρειες Προϊόντος
GuardShield Safe 2 - 445L Series
The GuardShield Safe 2 safety light curtain is a self-contained safety light curtain in a robust housing with an integrated laser alignment system. The Type 2 designation means that this particular safety light curtain meets a lesser requirement for performance under fault conditions than the GuardShield Type 4 safety light curtains. As a result, the GuardShield Type 2 safety light curtain can only be applied in applications where a formal risk assessment has determined that a Type 2 device is sufficient to meet the level of risk posed by the hazard.
Standards
IEC/EN61496 Parts 1 and 2, UL61496 Parts 1 and 2, UL1998
Light Curtain
P.O.A.
1
P.O.A.
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη
1
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη
Τεχνικό φυλλάδιο
Προδιαγραφές
Range
GuardShield
Series
micro 400
Beam Resolution
30mm
Component Type
Receiver, Sender
Safety Type
2
SIL IEC 61508
2
PL EN ISO 13849-1
d
Number Of Beams
32
Protective Height
480mm
Minimum Scanning Distance
0m
Maximum Scanning Distance
18m
Maximum Response Time
15.8 ms
Length
40mm
Supply Voltage
24 V dc
Height
650mm
Dimensions
30 x 40 x 650 mm
Application
Hand
Width
30mm
Terminal Type
5-Pin M12 Connector
Χώρα Προέλευσης
Switzerland
Λεπτομέρειες Προϊόντος
GuardShield Safe 2 - 445L Series
The GuardShield Safe 2 safety light curtain is a self-contained safety light curtain in a robust housing with an integrated laser alignment system. The Type 2 designation means that this particular safety light curtain meets a lesser requirement for performance under fault conditions than the GuardShield Type 4 safety light curtains. As a result, the GuardShield Type 2 safety light curtain can only be applied in applications where a formal risk assessment has determined that a Type 2 device is sufficient to meet the level of risk posed by the hazard.
Standards
IEC/EN61496 Parts 1 and 2, UL61496 Parts 1 and 2, UL1998