Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
CrouzetMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
SPDT
Voltage Sensing Range
183 → 528V ac
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Asymmetry, Phase Failure, Phase Sequence
Time Delay
0.1 → 10s
Series
MWG
Height
92.6mm
Length
69mm
Minimum Voltage Sensed
183V ac
Operating Temperature Range
+50°C
Minimum Operating Temperature
-20°C
Width
17.5mm
Maximum Operating Temperature
+50°C
Dimensions
69 x 17.5 x 92.6mm
Maximum Voltage Sensed
528V ac
Χώρα Προέλευσης
Indonesia
Λεπτομέρειες Προϊόντος
Multi Function Phase Control Relays 17.5mm - C-Lynx
3 phase network control relays monitor: the correct sequence of phases L1, L2, L3, the total phase failure - Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay and Asymmetry rate from 5% to 15% of Under Voltage Relay. LEDs are used for fault signalling, if a fault persists for longer than the threshold crossing delay configured by the operator, the output relay opens and the LED R is extinguished.
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη
Παρακαλούμε ελέγξτε ξανά αργότερα.
€ 159,05
Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
€ 197,22
Μονάδας (Including VAT) Με Φ.Π.Α
1
€ 159,05
Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
€ 197,22
Μονάδας (Including VAT) Με Φ.Π.Α
1
Αγοράστε μαζικά
Quantity Ποσότητα | Τιμή μονάδας |
---|---|
1 - 4 | € 159,05 |
5 - 9 | € 153,40 |
10 - 24 | € 147,56 |
25 - 49 | € 141,43 |
50+ | € 135,10 |
Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
CrouzetMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
SPDT
Voltage Sensing Range
183 → 528V ac
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Asymmetry, Phase Failure, Phase Sequence
Time Delay
0.1 → 10s
Series
MWG
Height
92.6mm
Length
69mm
Minimum Voltage Sensed
183V ac
Operating Temperature Range
+50°C
Minimum Operating Temperature
-20°C
Width
17.5mm
Maximum Operating Temperature
+50°C
Dimensions
69 x 17.5 x 92.6mm
Maximum Voltage Sensed
528V ac
Χώρα Προέλευσης
Indonesia
Λεπτομέρειες Προϊόντος
Multi Function Phase Control Relays 17.5mm - C-Lynx
3 phase network control relays monitor: the correct sequence of phases L1, L2, L3, the total phase failure - Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay and Asymmetry rate from 5% to 15% of Under Voltage Relay. LEDs are used for fault signalling, if a fault persists for longer than the threshold crossing delay configured by the operator, the output relay opens and the LED R is extinguished.