Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
CrouzetMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
DPDT
Voltage Sensing Range
194 → 528 V
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Asymmetry, Phase Failure, Phase Sequence
Time Delay
0.1 → 10s
Series
HWUA
Height
92.6mm
Length
69mm
Minimum Voltage Sensed
194 V
Operating Temperature Range
+50°C
Minimum Operating Temperature
-20°C
Width
35mm
Maximum Operating Temperature
+50°C
Dimensions
69 x 35 x 92.6mm
Maximum Voltage Sensed
528V
Λεπτομέρειες Προϊόντος
Multi Function Phase Control Relays 35mm - C-Lynx
The HWUA 3 phase network control relay monitors:- The correct sequence of phases L1, L2, L3,- Total phase failure,- Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay,- Asymmetry rate from 5% to 15% of Under Voltage Relay,- Faults are signalled via LEDs, distinguishing the origin of the fault. If a fault persists for longer than the threshold crossing delay configured by the operator, both output relays open and LED R is extinguished.
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη
Παρακαλούμε ελέγξτε ξανά αργότερα.
€ 306,03
Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
€ 379,48
Μονάδας Με Φ.Π.Α
1
€ 306,03
Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
€ 379,48
Μονάδας Με Φ.Π.Α
1
Αγοράστε μαζικά
Quantity Ποσότητα | Τιμή μονάδας |
---|---|
1 - 4 | € 306,03 |
5 - 9 | € 295,21 |
10 - 24 | € 283,87 |
25 - 49 | € 272,12 |
50+ | € 259,87 |
Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
CrouzetMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
DPDT
Voltage Sensing Range
194 → 528 V
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Phase Sensitivity
Phase Asymmetry, Phase Failure, Phase Sequence
Time Delay
0.1 → 10s
Series
HWUA
Height
92.6mm
Length
69mm
Minimum Voltage Sensed
194 V
Operating Temperature Range
+50°C
Minimum Operating Temperature
-20°C
Width
35mm
Maximum Operating Temperature
+50°C
Dimensions
69 x 35 x 92.6mm
Maximum Voltage Sensed
528V
Λεπτομέρειες Προϊόντος
Multi Function Phase Control Relays 35mm - C-Lynx
The HWUA 3 phase network control relay monitors:- The correct sequence of phases L1, L2, L3,- Total phase failure,- Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay,- Asymmetry rate from 5% to 15% of Under Voltage Relay,- Faults are signalled via LEDs, distinguishing the origin of the fault. If a fault persists for longer than the threshold crossing delay configured by the operator, both output relays open and LED R is extinguished.