Eaton RCCB, 40A, 4 Pole, 300mA, Type B
Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
EatonCircuit Breaker Type
RCCB
Current Rating
40A
Number of Poles
4
Range
FRCdM
Trip Sensitivity
300mA
Tripping Characteristics
Type B
Series
Eaton Moeller
Overall Depth
80mm
Breaking Capacity at Maximum Voltage Rating
500 A
Overall Dimensions
70 x 76 x 80mm
Terminal Contact Type
Screw
Overall Length
70mm
Break Time
Time Delay
Mounting Style
DIN Rail Mount
Rated DC Voltage
220V
Rated AC Voltage
240V
Overall Width
76mm
Χώρα Προέλευσης
Czech Republic
Λεπτομέρειες Προϊόντος
Eaton Residual Current Circuit Breakers (RCDs) - FRCdM Series Types B, B+ and Bfq
The FRCdM series of residual current devices from Eaton form part of the xEffect range providing the highest RCD protection for both people and appliances. These devices allow for permanent indication of actual electrical leakage with built in digital features.These types B, B+ and Bfq RCCBs detect AC pulsating, DC residual and smooth DC residual currents.
Type B RCCBs are the standard type and are sensitive to all residual current flows up to 1 kHZ. Type B+ devices are sensitive to all residual currents while also being equipped with a special tripping curve that limits the trip current to max. 420 mA for frequencies up to 20 kHz (Type B+ also meets superior fire protection regulations according to VDE 0664-400). Type Bfq devices meanwhile can tolerate system-induced earth leakage currents at higher frequencies up to 50 kHz.
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη
Παρακαλούμε ελέγξτε ξανά αργότερα.
€ 1.007,28
Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
€ 1.249,03
Μονάδας (Including VAT) Με Φ.Π.Α
1
€ 1.007,28
Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
€ 1.249,03
Μονάδας (Including VAT) Με Φ.Π.Α
1
Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
EatonCircuit Breaker Type
RCCB
Current Rating
40A
Number of Poles
4
Range
FRCdM
Trip Sensitivity
300mA
Tripping Characteristics
Type B
Series
Eaton Moeller
Overall Depth
80mm
Breaking Capacity at Maximum Voltage Rating
500 A
Overall Dimensions
70 x 76 x 80mm
Terminal Contact Type
Screw
Overall Length
70mm
Break Time
Time Delay
Mounting Style
DIN Rail Mount
Rated DC Voltage
220V
Rated AC Voltage
240V
Overall Width
76mm
Χώρα Προέλευσης
Czech Republic
Λεπτομέρειες Προϊόντος
Eaton Residual Current Circuit Breakers (RCDs) - FRCdM Series Types B, B+ and Bfq
The FRCdM series of residual current devices from Eaton form part of the xEffect range providing the highest RCD protection for both people and appliances. These devices allow for permanent indication of actual electrical leakage with built in digital features.These types B, B+ and Bfq RCCBs detect AC pulsating, DC residual and smooth DC residual currents.
Type B RCCBs are the standard type and are sensitive to all residual current flows up to 1 kHZ. Type B+ devices are sensitive to all residual currents while also being equipped with a special tripping curve that limits the trip current to max. 420 mA for frequencies up to 20 kHz (Type B+ also meets superior fire protection regulations according to VDE 0664-400). Type Bfq devices meanwhile can tolerate system-induced earth leakage currents at higher frequencies up to 50 kHz.