Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max

Κωδικός Προϊόντος της RS: 410-517Κατασκευαστής: ParkerΚωδικός Κατασκευαστή: PRT-A10
brand-logo
View all in Pneumatic Timers

Τεχνικό φυλλάδιο

Προδιαγραφές

Brand

Parker

Maximum Time

30s

Minimum Time

0.1s

Maximum Operating Temperature

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-15°C

Λεπτομέρειες Προϊόντος

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη

Παρακαλούμε ελέγξτε ξανά αργότερα.

Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη

€ 338,37

Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α

€ 419,58

Μονάδας (Including VAT) Με Φ.Π.Α

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max

€ 338,37

Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α

€ 419,58

Μονάδας (Including VAT) Με Φ.Π.Α

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη

Αγοράστε μαζικά

Quantity ΠοσότηταΤιμή μονάδας
1 - 4€ 338,37
5+€ 329,85

Τεχνικό φυλλάδιο

Προδιαγραφές

Brand

Parker

Maximum Time

30s

Minimum Time

0.1s

Maximum Operating Temperature

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-15°C

Λεπτομέρειες Προϊόντος

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.