Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
pico TechnologyProduct Type
Current Probe
Maximum DC Current
30A
Maximum AC Current
3kA
Accuracy
±1 %
Connector Type
D9
Minimum Operating Temperature
0°C
Maximum Operating Temperature
50°C
Model Number
TA325
Standards/Approvals
No
Safety Category Level
CAT III, CAT IV
Safety Category Voltage
600, 1V
Χώρα Προέλευσης
United Kingdom
Λεπτομέρειες Προϊόντος
The TA325 is a 3-phase AC current probe utilizing the Rogowski Coil principle, used to measure AC current up to 3000 A when used with oscilloscopes, recorders or data loggers. The flexible probe allows current measurements on hard-to-reach conductors. ;Rogowski Coil technology has a couple of advantages over CT (current transformer) technology: when measuring multiple phases, the phase difference is small and predictable for higher frequency harmonic analysis applications; also, Rogowski Coils do not have magnetic materials to saturate and so have excellent linearity. ;The probes provide a 3 V full-scale AC output proportional to the current being measured with three selectable ranges: 30 A, 300 A and 3000 A. ;When using the TA325 with a PicoScope 4444 differential scope, ensure that you purchase three TA271 D9-BNC adaptors. These can be found under the Accessories tab on this page.
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη
€ 1.279,67
€ 1.279,67 Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
€ 1.586,79
€ 1.586,79 Μονάδας Με Φ.Π.Α
1
€ 1.279,67
€ 1.279,67 Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
€ 1.586,79
€ 1.586,79 Μονάδας Με Φ.Π.Α
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη
1
Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
pico TechnologyProduct Type
Current Probe
Maximum DC Current
30A
Maximum AC Current
3kA
Accuracy
±1 %
Connector Type
D9
Minimum Operating Temperature
0°C
Maximum Operating Temperature
50°C
Model Number
TA325
Standards/Approvals
No
Safety Category Level
CAT III, CAT IV
Safety Category Voltage
600, 1V
Χώρα Προέλευσης
United Kingdom
Λεπτομέρειες Προϊόντος
The TA325 is a 3-phase AC current probe utilizing the Rogowski Coil principle, used to measure AC current up to 3000 A when used with oscilloscopes, recorders or data loggers. The flexible probe allows current measurements on hard-to-reach conductors. ;Rogowski Coil technology has a couple of advantages over CT (current transformer) technology: when measuring multiple phases, the phase difference is small and predictable for higher frequency harmonic analysis applications; also, Rogowski Coils do not have magnetic materials to saturate and so have excellent linearity. ;The probes provide a 3 V full-scale AC output proportional to the current being measured with three selectable ranges: 30 A, 300 A and 3000 A. ;When using the TA325 with a PicoScope 4444 differential scope, ensure that you purchase three TA271 D9-BNC adaptors. These can be found under the Accessories tab on this page.