Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
PR ElectronicsNumber of Channels
2
Module Type
Isolated Driver
Barrier Type
Galvanic Barrier
Output Signal Type
Current, Voltage
Maximum Voltage
250V ac
Hazardous Area Certification
ATEX
Input Signal Type
Current, Voltage
Supply Voltage
19.2 → 300 V dc, 21.6 → 253V ac
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+60°C
Safety Current Maximum
400mA
Safety Voltage Maximum
250 V ac
Series
5100
Operating Temperature Range
-20 → +60°C
Χώρα Προέλευσης
Denmark
Λεπτομέρειες Προϊόντος
PR Electronics 5105B Ex-isolated Driver
PR Electronics 5105B intrinsically safe isolated driver is a safety barrier for current signals transmitted to I/P converters and displays mounted in hazardous area. The 5105B signal conditioner is based on microprocessor technology for gain and offset. The analogue signal is transmitted at a response time of less than 25 ms. 20 factory-calibrated measurement ranges in the 5105A can be selected by the internal DIP-switches without the need for recalibration. Mounted vertically or horizontally on a DIN rail. As the devices can be mounted without distance between neighbouring units, up to 84 channels can be mounted per meter.
PR Electronics - Ex Interfaces
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη
Παρακαλούμε ελέγξτε ξανά αργότερα.
P.O.A.
1
P.O.A.
1
Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
PR ElectronicsNumber of Channels
2
Module Type
Isolated Driver
Barrier Type
Galvanic Barrier
Output Signal Type
Current, Voltage
Maximum Voltage
250V ac
Hazardous Area Certification
ATEX
Input Signal Type
Current, Voltage
Supply Voltage
19.2 → 300 V dc, 21.6 → 253V ac
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+60°C
Safety Current Maximum
400mA
Safety Voltage Maximum
250 V ac
Series
5100
Operating Temperature Range
-20 → +60°C
Χώρα Προέλευσης
Denmark
Λεπτομέρειες Προϊόντος
PR Electronics 5105B Ex-isolated Driver
PR Electronics 5105B intrinsically safe isolated driver is a safety barrier for current signals transmitted to I/P converters and displays mounted in hazardous area. The 5105B signal conditioner is based on microprocessor technology for gain and offset. The analogue signal is transmitted at a response time of less than 25 ms. 20 factory-calibrated measurement ranges in the 5105A can be selected by the internal DIP-switches without the need for recalibration. Mounted vertically or horizontally on a DIN rail. As the devices can be mounted without distance between neighbouring units, up to 84 channels can be mounted per meter.