RS PRO Oscilloscope Probe, Differential, High Voltage Type, 50MHz, 1:10, 1:100
Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
RS ProProbe Type
Differential, High Voltage
Attenuation
1:10, 1:100
Bandwidth
50MHz
Maximum Common Mode Input Voltage
1.5kV
Number of Probes
1
Χώρα Προέλευσης
China
Λεπτομέρειες Προϊόντος
RS Pro DC-50 MHz High Voltage Differential Probe RSDPB4080
RS Pro high-voltage differential probes are designed for the measurement of high-voltage differential signal, to meet the demand for floating measurement. The high bandwidth meets the demand for most measurement systems.
The probes are equipped with standard BNC input connectors. They can be used with any manufacturer oscilloscope (oscilloscope input impedance should set to 1 MΩ. When 50 Ω is selected, the attenuation multiply attenuates doubles) to test waveform of the tested circuits. There is an automatic save function, to prevent users reoperating in case of power supply drops. The probes have good capability of common mode noise suppression and can be widely used in the research and development, debugging or overhauling work for switching power supply, frequency converter, electronic ballast, frequency conversion electronic appliances and other electric power equipment.
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη
Παρακαλούμε ελέγξτε ξανά αργότερα.
€ 781,01
Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
€ 968,45
Μονάδας Με Φ.Π.Α
1
€ 781,01
Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α
€ 968,45
Μονάδας Με Φ.Π.Α
1
Τεχνικό φυλλάδιο
Προδιαγραφές
Brand
RS ProProbe Type
Differential, High Voltage
Attenuation
1:10, 1:100
Bandwidth
50MHz
Maximum Common Mode Input Voltage
1.5kV
Number of Probes
1
Χώρα Προέλευσης
China
Λεπτομέρειες Προϊόντος
RS Pro DC-50 MHz High Voltage Differential Probe RSDPB4080
RS Pro high-voltage differential probes are designed for the measurement of high-voltage differential signal, to meet the demand for floating measurement. The high bandwidth meets the demand for most measurement systems.
The probes are equipped with standard BNC input connectors. They can be used with any manufacturer oscilloscope (oscilloscope input impedance should set to 1 MΩ. When 50 Ω is selected, the attenuation multiply attenuates doubles) to test waveform of the tested circuits. There is an automatic save function, to prevent users reoperating in case of power supply drops. The probes have good capability of common mode noise suppression and can be widely used in the research and development, debugging or overhauling work for switching power supply, frequency converter, electronic ballast, frequency conversion electronic appliances and other electric power equipment.