Schneider Electric Choke for Use with Altivar 61 Series, 155mm Length, 3-Phase, 200 → 690 V

Κωδικός Προϊόντος της RS: 656-0722Κατασκευαστής: Schneider ElectricΚωδικός Κατασκευαστή: VW3A4554
brand-logo
View all in Motor Accessories

Τεχνικό φυλλάδιο

Προδιαγραφές

Accessory Type

Choke

For Use With

Altivar 61 Series

Voltage Range

200 → 690 V

Electrical Phase

3

Length

155mm

Depth

135mm

Dimensions

155 x 170 x 135 mm

Χώρα Προέλευσης

France

Λεπτομέρειες Προϊόντος

Altivar AC Line Choke

A line choke can be used to provide improved protection against overvoltages on the line supply and to reduce the current harmonics produced by the drive. The recommended chokes can be used to limit the line current. They have been developed in line with standard EN 50178 (VDE 0160 level 1 high energy overvoltages on the line supply). The inductance values are defined for a voltage drop between phases of between 3% and 5% of the nominal line voltage. Values higher than this will cause loss of torque. These chokes should be installed upstream of the drive.

Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη

Παρακαλούμε ελέγξτε ξανά αργότερα.

Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη

€ 503,24

Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α

€ 624,02

Μονάδας (Including VAT) Με Φ.Π.Α

Schneider Electric Choke for Use with Altivar 61 Series, 155mm Length, 3-Phase, 200 → 690 V

€ 503,24

Μονάδας (Exc. Vat)Χωρίς Φ.Π.Α

€ 624,02

Μονάδας (Including VAT) Με Φ.Π.Α

Schneider Electric Choke for Use with Altivar 61 Series, 155mm Length, 3-Phase, 200 → 690 V
Ημερομηνία αποθέματος προσωρινά μη διαθέσιμη

Αγοράστε μαζικά

Quantity ΠοσότηταΤιμή μονάδας
1 - 4€ 503,24
5 - 9€ 496,76
10+€ 490,69

Τεχνικό φυλλάδιο

Προδιαγραφές

Accessory Type

Choke

For Use With

Altivar 61 Series

Voltage Range

200 → 690 V

Electrical Phase

3

Length

155mm

Depth

135mm

Dimensions

155 x 170 x 135 mm

Χώρα Προέλευσης

France

Λεπτομέρειες Προϊόντος

Altivar AC Line Choke

A line choke can be used to provide improved protection against overvoltages on the line supply and to reduce the current harmonics produced by the drive. The recommended chokes can be used to limit the line current. They have been developed in line with standard EN 50178 (VDE 0160 level 1 high energy overvoltages on the line supply). The inductance values are defined for a voltage drop between phases of between 3% and 5% of the nominal line voltage. Values higher than this will cause loss of torque. These chokes should be installed upstream of the drive.